2.2 Supplemental
Note: Specifications listed below are typical and not guaranteed.
Parameter
Supplemental Specification
Line Frequency:
63 - 300 Hz (derate maximum output power 5%)
300 - 440 Hz (derate maximum output power 10%)
Output Voltage Accuracy
(versus output frequency):
± 1% of full scale (2000 - 4000 Hz),
± 5% of full scale (4000 - 5000 Hz)
Output Load Regulation
(versus output frequency):
± 2% (500 - 1000 Hz),
± 5% (1000 - 2000 Hz),
± 10% (2000 - 4000 Hz)
± 20% (4000 - 5000 Hz)
Measurement Accuracy:
Stated ± 5% of full scale (16 - 300 Hz),
Stated ± 1% of full scale (500 - 5000 Hz)