Revision L
January 2010
Copyright © 2006-2010
AMETEK
®
Programmable Power Division.
All rights reserved.
P/N 6005-961
AMETEK Programmable Power Division 1
Compact i/iX
AC and DC Power Source
Programming Manual
TEL: +1 (858) 458-0223
Email: sales@programmablepower.com
Web Site: www.programmablepower.com
Vista de pagina 0
1 2 3 4 5 6 ... 215 216

Indice de contenidos

Pagina 1 - Programming Manual

Revision L January 2010 Copyright © 2006-2010 AMETEK® Programmable Power Division. All rights reserved. P/N 6005-961 AMETEK Programmable Po

Pagina 2

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 10 The above two documents are available from the IEEE (Institute of

Pagina 3

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 100 Note: Setting a bit in the PTR or NTR filter can of itself gener

Pagina 4 - WARNING

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 101 4.25 System Commands The system commands control the system-leve

Pagina 5 - PRODUCT RETURN PROCEDURE

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 102 Command Syntax SYSTem:COMMunicate:LAN:ADDRess <NRF> Parame

Pagina 6

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 103 This command will set the LAN Gateway address. The query format r

Pagina 7

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 104 Command Syntax SYSTem:COMMunicate:SERial:PARity <parity> P

Pagina 8

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 105 SYSTem:ETIMe? This command will return the total number of accumu

Pagina 9 - 1. Introduction

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 106 This command can only be used with the USB or LAN interface. It l

Pagina 10 - 1.2.3 Hardware differences

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 107 4.26 Trace Subsystem Commands This subsystem programs the output

Pagina 11

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 108 TRACe:CATalog DATA:CATalog These commands return a list of define

Pagina 12

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 109 4.27 Trigger Subsystem This subsystem controls the triggering of

Pagina 13 - 2. Introduction to SCPI

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 11 This manual contains sections on programming the compact iX or i S

Pagina 14 - 2.2.3 The SCPI Command Tree

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 110 The INITiate commands control the initiation of both the transien

Pagina 15

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 111 TRIGger When the trigger subsystem has been initiated, the TRIGge

Pagina 16 - 2.4 Coupled Commands

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 112 TRIGger:SEQuence2:SOURce TRIGger:SYNChronize:SOURce These comman

Pagina 17 - 2.5.3 Headers

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 113 Command Syntax TRIGger:SEQuence3[:IMMediate] TRIGger:ACQuire[:I

Pagina 18 - 2.5.7 Message Terminator

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 114 5. Common Commands Common commands begin with an * and consist o

Pagina 19 - 2.6 SCPI Data Formats

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 115 5.1 *CLS This command clears the following registers (see chapte

Pagina 20 - 3. System Considerations

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 116 5.2 *ESR? This query reads the Standard Event Status Event regis

Pagina 21 - 3.2 USB Interface

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 117 5.5 *OPT? This query requests the AC Source to identify any opti

Pagina 22

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 118 5.7 *RCL Warning Recalling a previously stored state may place

Pagina 23

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 119 5.8 *RST This command resets the AC source to the factory-define

Pagina 24

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 12 1.4.2 USB Capabilities of the AC source All AC source functions

Pagina 25

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 120 5.9 *SAV This command stores the present state of the AC source

Pagina 26

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 121 5.11 *STB? This query reads the Status Byte register, which cont

Pagina 27 - 3.2.2 USB Interface Use

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 122 5.14 *WAI This command instructs the AC source not to process an

Pagina 28 - 3.4 LAN Option

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 123 6. Programming Examples 6.1 Introduction This chapter contains

Pagina 29

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 124 The AC source can be programmed to turn off its output if the ac

Pagina 30

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 125 Output voltage changes caused by the OUTPut:STATe command, by a p

Pagina 31

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 126 Data points can be in any arbitrary units. The AC source scales t

Pagina 32 - 3.4.5 Socket Port Number

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 127 The PHASe command sets the relative phase of each of the outputs.

Pagina 33 - 4. SCPI Command Reference

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 128 are sent, no error will be generated because the second VOLTage:R

Pagina 34 - 4.2 Subsystem Commands

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 129 6.4.1 Transient System Model Figure 6-1 is a model of the transi

Pagina 35 - 4.3 Calibration Subsystem

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 13 2. Introduction to SCPI SCPI (Standard Commands for Programmable

Pagina 36

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 130 6.5 Step and Pulse Transients Proceed as follows to setup step a

Pagina 37 - 4.4 Diagnostic Subsystem

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 131 INIT:SEQ1 Set to Wait-for-trigger state <device trigger>

Pagina 38 - 4.5 Display Subsystem

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 132 6.6 List Transients List mode lets you generate complex sequence

Pagina 39

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 133 4. Determine the number of times the list is repeated before it

Pagina 40 - 4.6 Instrument Subsystem

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 134 6.7.2 Output Trigger System Model Figure 6-2 is a model of the o

Pagina 41 - 4.7 Limit Subsystem

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 135 6.7.3 Initiating the Output Trigger System When the AC source is

Pagina 42

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 136 6.7.5 Specifying a Trigger Delay A time delay can be programmed

Pagina 43

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 137 6.7.7 Generating Triggers Providing that you have specified the

Pagina 44

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 138 6.8 Making Measurements The AC source has the capability to retu

Pagina 45

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 139 6.8.2 Power Measurements The MEASure and FETCh queries can retur

Pagina 46

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 14 2.2.3 The SCPI Command Tree As previously explained, the basic SC

Pagina 47

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 140 6.8.4 Simultaneous Output Phase Measurements You can return simu

Pagina 48

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 141 6.8.7 SCPI Measurement Triggering Nomenclature As previously exp

Pagina 49

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 142 6.8.9 Initiating the Measurement Trigger System When the AC sour

Pagina 50

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 143 6.8.12 Using the DFI Output to Indicate Error Conditions The Dis

Pagina 51

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 144 6.9 Controlling the Instantaneous Voltage and Current Data Buffe

Pagina 52

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 145 6.9.2 VB6 Sample: Converting IEEE format trace data to floating

Pagina 53

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 146 End If 'Append number sign and return value If sign Th

Pagina 54

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 147 6.9.4 Pre-event and Post-event Triggering The range for this of

Pagina 55

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 148 6.10 Downloading Arbitrary Waveforms The compact iX Series suppo

Pagina 56

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 149 For i = 0 to iPoints –1 strCmd = strCmd + "," + FrmO

Pagina 57

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 15 2. OUTPut:PROTection:DELay 20. The entire message would be: OUT

Pagina 58

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 150 7. Programming the Status and Event Registers You can use status

Pagina 59

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 151 Figure 7-1: Status Register Model.

Pagina 60 - 4.13 Output Subsystem

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 152 Bit Signal Meaning Operation Status Group 0 CAL Interface i

Pagina 61

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 153 7.3 Questionable Status Group The Questionable Status registers

Pagina 62

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 154 7.4 Questionable Instrument Isummary Status Group Although only

Pagina 63

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 155 7.5 Standard Event Status Group This group consists of an Event

Pagina 64 - 4.14 Power On Subsystem

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 156 7.6 Status Byte Register This register summarizes the informatio

Pagina 65

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 157 7.7 Examples 7.7.1 Determining the Cause of a Service Interrupt

Pagina 66

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 158 7.7.3 Monitoring Both Phases of a Status Transition You can moni

Pagina 67

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 159 TRIGger:ACQuire:SOURce TTLT Figure 7-2: Trigger Model.

Pagina 68

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 16 2.3 Using Queries Observe the following precautions with queries:

Pagina 69

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 160 7.8 Remote Inhibit and Discrete Fault Indicator The remote inhib

Pagina 70

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 161 7.9 SCPI Command Completion SCPI commands sent to the AC source

Pagina 71

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 162 8. Option Commands 8.1 Introduction The i and iX Series offer a

Pagina 72

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 163 8.2 RTCA/DO-160D (-160) The following are the remote commands av

Pagina 73

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 164 8.2.2 DO160 Normal Test Commands DO160:NORMal:VOLT_FREQ:MINimum

Pagina 74

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 165 DO160:NORMal:VOLTage:INTerrupt This command will cause output vol

Pagina 75

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 166 DO160:NORMal:FREQuency:VARiation This command applies to Group 2

Pagina 76

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 167 8.2.3 DO160 Emergency Test Commands DO160:EMERgency:VOLT_FREQ:MI

Pagina 77

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 168 8.2.4 DO160 Abnormal Test Commands DO160:ABNormal:VOLTage:MINimu

Pagina 78

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 169 DO160:ABNormal:FREQuency:TRANsient This command applies to Group

Pagina 79

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 17 Figure 2-2: Command Message Structure The basic parts of the abov

Pagina 80

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 170 8.3 MIL-STD 704 Rev D - F (-704) The following are the remote co

Pagina 81

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 171 :MODulation :TRANsient :VOLTage [:LOW] :HIGH :FR

Pagina 82

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 172 8.3.3 MIL704 Steady State Commands MIL704:SSTate:VOLTage This co

Pagina 83

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 173 MIL704:SSTate:WAVeform[:DISTortion] This command will set the vol

Pagina 84

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 174 MIL704:TRANsient:FREQuency[:LOW] This command will set the low fr

Pagina 85

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 175 MIL704:ABNormal:FREQuency:OVER This command will set the high fre

Pagina 86

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 176 8.4 MIL-STD 704 Rev A - F (-704F) The following are the remote c

Pagina 87

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 177 8.4.1 Command Tree MS704 :ABNormal :LIMits [:ALL] :NO

Pagina 88

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 178 :FAIL [:COMBination] [:ALL] :ONE :TWO

Pagina 89

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 179 8.4.2 MS704 General Commands A number of MS704 commands are avai

Pagina 90

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 18 combine two or more message units into a compound message, you may

Pagina 91

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 180 MS704:REVision This command sets the RTCA DO-160 test standard re

Pagina 92

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 181 MS704:TEST:CONDition This command sets the desired test condition

Pagina 93

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 182 8.4.3 MS704 Steady State Commands Steady state tests can be star

Pagina 94

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 183 MS704:NORMal:VOLTage:PHASe:DIFFerence This command will run the s

Pagina 95

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 184 MS704:NORMal:VOLTage:TRANsient:COMBination This command will run

Pagina 96

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 185 8.4.4 MS704 Abnormal State Commands Abnormal state tests can be

Pagina 97

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 186 Command Syntax MS704:ABNormal:VOLTage:TRANsient:OVER Parameters

Pagina 98

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 187 Command Syntax MS704:ABNormal:FREQuency:TRANsient:COMBination P

Pagina 99

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 188 MS704:EMERgency:LIMit:NOMinal This command will run the emergency

Pagina 100

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 189 MS704:POWer:FAIL[:COMBination]:TWO This command will run the powe

Pagina 101 - 4.25 System Commands

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 19 2.6 SCPI Data Formats All data programmed to or returned from the

Pagina 102

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 190 8.5 Airbus ABD0100.1.8 Test Option (-A350) The –A350 option is i

Pagina 103

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 191 8.6 Airbus ABD0100.1.8 Test Option (-ABD) The -ABD option is imp

Pagina 104

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 192 8.7 Airbus AMD24 Test Option (-AMD) The -AMD option is implement

Pagina 105

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 193 8.8 Boeing B787-0147 Test Option (-B787) The -ABD option is impl

Pagina 106

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 194 8.9 Altas Based Language Extensions Option (-ABL) 8.9.1 Introdu

Pagina 107

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 195 8.9.2 ABLE Language details The following commands are supported

Pagina 108

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 196 SYNTAX DESCRIPTION UNLK Will enable the fault generated by the

Pagina 109 - 4.27 Trigger Subsystem

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 197 SYNTAX DESCRIPTION TEST 7 Returns phase A measured power. TEST

Pagina 110 - (default)

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 198 8.9.3 Language Extension The following additional capabilities –

Pagina 111

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 199 8.10 Watt Hour Meter (-WHM) The following SCPI command may be us

Pagina 112

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 2 Refers to: Models: 751i AC and DC Power Source 751iX AC and DC Po

Pagina 113

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 20 3. System Considerations This chapter addresses some system issue

Pagina 114 - 5. Common Commands

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 200 Appendix A : SCPI Command tree SCPI Common Commands *CLS *ESE &

Pagina 115 - 5.1 *CLS

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 201 [:REAL]? :APParent? :REACtive? :PFACtor? :TOTal? :VOLTage [:DC]?

Pagina 116 - 5.4 *OPC

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 202 :CLEar :DELay <n> :RI :MODE LATCHing | LIVE | OFF TTLTrig M

Pagina 117 - 5.6 *PSC

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 203 :ERRor? :LANGuage SCPI | APEN :REMote :RWLOCK :TEMPerature? :VERS

Pagina 118 - 5.7 *RCL

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 204 Appendix B : SCPI Conformance Information SCPI Version The power

Pagina 119 - 5.8 *RST

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 205 Non-SCPI commands. CAL:MEAS:CURR CAL:MEAS:CURR:SPH CAL:MEAS:VOLT

Pagina 120 - 5.10 *SRE

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 206 MS704:EMER[:ALL] MS704:EMER:NOM MS704:EMER:LOW MS704:EMER:HIGH MS

Pagina 121 - 5.13 *TST?

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 207 Appendix C : Error Messages This appendix gives the error number

Pagina 122 - 5.14 *WAI

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 208 Number Message String Cause Remedy -120 "Numeric data er

Pagina 123 - 6. Programming Examples

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 209 Number Message String Cause Remedy -255 “Directory full” Too

Pagina 124

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 21 3.2 USB Interface Unlike RS232, there are no generic drivers avai

Pagina 125 - 6.2.1 Waveform Shapes

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 210 Number Message String Cause Remedy output 3” Master source ha

Pagina 126 - 6.2.2 Individual Phases

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 211 Number Message String Cause Remedy 815 "Slew time exceed

Pagina 127 - 6.3 Coupled Commands

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 212 Index * *CLS...

Pagina 128

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 213 FETCh:CURRent:AMPLitude:RESet ...50 FETCh:CURRent:CRESt

Pagina 129

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 214 MEASure:CURRent:AMPLitude:MAXimum?.50 MEASure:CURRent:AMPLitude:R

Pagina 130

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 215 O OUTPut ...

Pagina 131

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 216 TRIGger:SEQuence2:SOURce...113 TRIGger:SEQuence3

Pagina 132 - 6.6 List Transients

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 22 USB Device Driver installation Plug in USB cable to power sour

Pagina 133

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 23 Select the second choice from the list to install the driver by

Pagina 134

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 24 For Windows XP OS, browse to the following location: C:\Program Fi

Pagina 135

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 25 Once completed, the dialog box shown above will appear signalin

Pagina 136

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 26 Figure 3-1: Windows XP Device Manager - USB Port

Pagina 137 - 6.7.7 Generating Triggers

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 27 3.2.2 USB Interface Use Note that the power source will be detect

Pagina 138 - 6.8 Making Measurements

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 28 3.3 RS232 Interface The RS232 is provided on 2253i and 2253iX mod

Pagina 139 - 6.8.3 Harmonic Measurements

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 29 3.4.3 Private Networks without DHCP servers If you are setting up

Pagina 140

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 3 About AMETEK AMETEK Programmable Power, Inc., a Division of AMETEK,

Pagina 141

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 30 below. IP Address Displays the IP address setting. This value ca

Pagina 142

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 31 = 16). This value can be changed by pressing the SET key and enter

Pagina 143

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 32 3.4.5 Socket Port Number Now that a connection has been verified,

Pagina 144

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 33 4. SCPI Command Reference 4.1 Introduction This chapter provides

Pagina 145

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 34 4.2 Subsystem Commands Subsystem commands are specific to AC sour

Pagina 146

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 35 4.3 Calibration Subsystem The commands in this subsystem allow yo

Pagina 147

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 36 Command Syntax CALibrate:MEASure:VOLTage Parameters None Query Sy

Pagina 148 - 6.10.2 Download Sample

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 37 4.4 Diagnostic Subsystem These subsystem commands perform diagnos

Pagina 149

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 38 4.5 Display Subsystem This subsystem allows text information to b

Pagina 150 - 7.2 Operation Status Group

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 39 DISPlay:TEXT This command sets the character string that is displa

Pagina 151

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 4 Important Safety Instructions Before applying power to the system,

Pagina 152

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 40 4.6 Instrument Subsystem This subsystem programs the three-phase

Pagina 153

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 41 4.7 Limit Subsystem These subsystem commands may be used to query

Pagina 154

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 42 120 Three phase mode. Determines relative phase angle between pha

Pagina 155

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 43 4.8 Array Measurement Subsystem This subsystem lets you retrieve

Pagina 156 - 7.6 Status Byte Register

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 44 Query Syntax MEASure:ARRay:CURRent[:DC]? [<n>,<n>] F

Pagina 157 - 7.7 Examples

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 45 SENSe:SWEep:TINTerval, and the position of the trigger relative to

Pagina 158

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 46 Syntax MEASure:ARRay:MODe Parameters BIN | ASCii Examples MEAS:

Pagina 159

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 47 If (c(1) And &H80) = &H80 Then expo = expo Or 1 '

Pagina 160 - 7.8.1 Remote Inhibit (RI)

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 48 Query Syntax MEASure:ARRay:VOLTage[:DC]? [<n>, <n>]

Pagina 161 - 7.9 SCPI Command Completion

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 49 4.9 Current Measurement Subsystem This subsystem programs the cur

Pagina 162 - 8. Option Commands

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 5 WARRANTY TERMS AMETEK Programmable Power, Inc. (“AMETEK”), provide

Pagina 163 - 8.2 RTCA/DO-160D (-160)

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 50 Query Syntax MEASure[:SCALar]:CURRent:AC? FETCh[:SCALar]:CURRent

Pagina 164

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 51 These queries return the output current crest factor. This is the

Pagina 165 - VOLTAGE SURGE, for details

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 52 Query Syntax MEASure[:SCALar]:CURRent:HARMonic:THD? FETCh[:SCALa

Pagina 166

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 53 be measured is dependent on the output frequency. Any harmonics th

Pagina 167

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 54 4.10 Frequency Measurement Subsystem This subsystem programs the

Pagina 168

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 55 4.11 Power Measurement Subsystem This subsystem programs the powe

Pagina 169

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 56 Query Syntax MEASure[:SCALar]:POWer:AC:APParent? FETCh[:SCALar]:

Pagina 170 - 8.3.1 Command Tree

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 57 4.12 Voltage Measurement Subsystem This subsystem programs the vo

Pagina 171

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 58 Query Syntax MEASure[:SCALar]:VOLTage:ACDC? FETCh[:SCALar]:VOLTa

Pagina 172

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 59 Query Syntax MEASure[:SCALar]:VOLTage:HARMonic:THD? FETCh[:SCALa

Pagina 173

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 6 Table of Contents 1. Introduction ...

Pagina 174

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 60 4.13 Output Subsystem This subsystem controls the main outputs, t

Pagina 175

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 61 OUTPut:DFI:SOURce This command selects the source for DFI events.

Pagina 176

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 62 OUTPut:PROTection:DELay This command sets the delay time between t

Pagina 177 - 8.4.1 Command Tree

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 63 OUTPut:TTLTrg[:STATe] This command enables or disables the AC sour

Pagina 178

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 64 4.14 Power On Subsystem This subsystem controls the specific conf

Pagina 179

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 65 PONSetup:RELay[:HOLD] This command is used to set a delay time bet

Pagina 180

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 66 4.15 Sense Subsystem - Sweep This subsystem controls the measurem

Pagina 181

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 67 Command Syntax SENSe:SWEep:OFFSet:POINts<NRf+> Parameters

Pagina 182

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 68 4.16 Source Subsystem - Current This subsystem programs the outpu

Pagina 183

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 69 CURRent:PROTection:STATe This command enables or disables the AC s

Pagina 184

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 7 5.8 *RST...

Pagina 185

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 70 4.17 Source Subsystem - Frequency This subsystem programs the out

Pagina 186

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 71 FREQuency:SLEW This command sets the rate at which frequency chang

Pagina 187

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 72 FREQuency:TRIGgered This command programs the frequency that the o

Pagina 188

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 73 4.18 Source Subsystem - Function This subsystem programs the outp

Pagina 189

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 74 LIST The waveform shape is controlled by the waveform shape list

Pagina 190

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 75 4.19 Source Subsystem - List This subsystem controls the generati

Pagina 191

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 76 LIST:COUNt This command sets the number of times that the list is

Pagina 192

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 77 Command Syntax [SOURce:]LIST:FREQuency[:LEVel]<NRf+>{,<N

Pagina 193

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 78 Command Syntax [SOURce:]LIST:PHASe<NRf+>{,<NRf+>} Par

Pagina 194 - 8.9.1 Introduction

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 79 This command specifies how the list sequencing responds to trigger

Pagina 195 - 8.9.2 ABLE Language details

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 8 Table of Figures Figure 2-1: Partial Command Tree...

Pagina 196

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 80 Command Syntax [SOURce:]LIST:VOLTage[:LEVel] <NRf+>{,<NR

Pagina 197

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 81 4.20 Source Subsystem - Mode The MODE command allows switching be

Pagina 198 - 8.9.3 Language Extension

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 82 4.21 Source Subsystem - Phase This subsystem programs the output

Pagina 199 - 8.10 Watt Hour Meter (-WHM)

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 83 Phase Selectable This command sets the output phase when a trigger

Pagina 200

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 84 4.22 Source Subsystem - Pulse This subsystem controls the generat

Pagina 201

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 85 Parameter Set Action DCYCle PERiod WIDTh √ Sets WIDTh. If W

Pagina 202

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 86 PULSe:WIDTh This command sets the width of a transient output puls

Pagina 203

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 87 4.23 Source Subsystem - Voltage This subsystem programs the outpu

Pagina 204

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 88 VOLTage:ALC:SOURce These commands select the source from which the

Pagina 205

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 89 VOLTage:TRIGgered Phase Selectable This command selects the ac rms

Pagina 206

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 9 1. Introduction This instruction manual (P/N 6005-961) contains pr

Pagina 207 - Appendix C : Error Messages

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 90 VOLTage:PROTection Phase Selectable This command sets the overvolt

Pagina 208

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 91 VOLTage:REFerance This command select the referance Voltage. The f

Pagina 209

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 92 VOLTage:SENSe:SOURce These commands select the source from which t

Pagina 210

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 93 VOLTage:SLEW:MODE Phase Selectable This command determines how the

Pagina 211

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 94 4.24 Status Subsystem Commands This subsystem programs the i/iX S

Pagina 212

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 95 Bit Position 15-9 8 7-6 5 4-1 0 CAL Interface is computing

Pagina 213

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 96 STATus:OPERation:NTR STATus:OPERation:PTR These commands set or re

Pagina 214

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 97 STATus:QUEStionable? This query returns the value of the Questiona

Pagina 215

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 98 Note: Setting a bit in the PTR or NTR filter can of itself genera

Pagina 216

Programming Manual Compact i / iX Series AMETEK Programmable Power Division 99 This query returns the value of the Questionable Condition registe

Comentarios a estos manuales

Sin comentarios