Programming Manual Compact i / iX Series
AMETEK Programmable Power Division 184
MS704:NORMal:VOLTage:TRANsient:COMBination
This command will run the steady state combination voltage transients test.
Command Syntax MS704:NORMal:VOLTage:TRANsient:COMBination
Parameters none
Examples MS704:NORM:VOLT:TRAN:COMB
Query Syntax none
MS704:NORMal:FREQuency:MODulation
This command will run the steady state frequency modulation test.
Command Syntax MS704:NORMal:FREQuency:MODulation
Parameters none
Examples MS704:NORM:FREQ:MOD
Query Syntax none
MS704:NORMal:FREQuency:TRANsient[:ALL]
This command will run all the steady state frequency transients tests.
Command Syntax MS704:NORMal:FREQuency:TRANsient[:ALL]
Parameters none
Examples MS704:NORM:FREQ:TRAN
Query Syntax none
MS704:NORMal:FREQuency:TRANsient:OVER
This command will run the steady state over frequency transients test.
Command Syntax MS704:NORMal:FREQuency:TRANsient:OVER
Parameters none
Examples MS704:NORM:FREQ:TRAN:OVER
Query Syntax none
MS704:NORMal:FREQuency:TRANsient:UNDer
This command will run the steady state under frequency transients test.
Command Syntax MS704:NORMal:FREQuency:TRANsient:UNDer
Parameters none
Examples MS704:NORM:FREQ:TRAN:UND
Query Syntax none
MS704:NORMal:FREQuency:TRANsient:COMBination
This command will run the steady state combination frequency transients test.
Command Syntax MS704:NORMal:FREQuency:TRANsient:COMBination
Parameters none
Examples MS704:NORM:FREQ:TRAN:COMB
Query Syntax none