Programming Manual Compact i / iX Series
AMETEK Programmable Power Division 111
TRIGger
When the trigger subsystem has been initiated, the TRIGger command generates a trigger signal
regardless of the selected trigger source.
Command Syntax TRIGger[:SEQuence1][:IMMediate]
TRIGger[:TRANsient][:IMMediate]
Parameters None
Examples TRIG TRIG:TRAN TRIG:SEQ1:IMM
Related Commands ABOR TRIG:SOUR TRIG:DEL TRIG:SYNC
TRIG:SYNC:PHAS INIT INIT:CONT *TRG *WAI
TRIGger:DELay
This command sets the time delay between the detection of a trigger signal and the start of any
corresponding trigger action. After the time delay has elapsed, the trigger is implemented unless
the trigger system is also waiting for a sync signal that has been specified by
TRIGger:SYNChronous:PHASe.
Command Syntax TRIGger[:SEQuence1]:DELay<NRf+>
TRIGger[:TRANsient]:DELay<NRf+>
Parameters 3-phase models: 0 to 1.07533E6|MINimum|MAXimum
1-phase models: 0 to 4.30133E5|MINimum|MAXimum
Unit s (seconds)
*RST Value 0
Examples TRIG:DEL .25 TRIG:DEL MAX TRIG:TRAN:DEL 1
Query Syntax TRIGger[:SEQuence1]:DELay?
TRIGger[:TRANsient]:DELay?
Returned Parameters <NR3>
Related Commands ABOR TRIG TRIG:SOUR TRIG:SYNC
TRIG:SYNC:PHAS INIT INIT:CONT *TRG *WAI
TRIGger:SOURce
This command selects the trigger source for the first sequence in generating a step, pulse, or list
output as follows:
BUS IEEE-488 device, *TRG, or <GET> (Group Execute Trigger)
EXTernal AC source's backpanel Trigger In1 SMA connector
IMMediate trigger is generated as soon as the trigger system is initiated.
Command Syntax TRIGger[:SEQuence1]:SOURce<CRD>
TRIGger[:TRANsient]:SOURce<CRD>
Parameters BUS | EXTernal | IMMediate
*RST Value BUS
Examples TRIG:SOUR BUS
TRIG:TRAN:SOUR EXT
Query Syntax TRIGger[:SEQuence1]:SOURce?
TRIGger[:TRANsient]:SOURce?
Returned Parameters <CRD>
Related Commands ABOR TRIG TRIG:DEL TRIG:SYNC
TRIG:SYNC:PHAS INIT INIT:CONT *TRG *WAI
Comentarios a estos manuales