Programming Manual Compact i / iX Series
AMETEK Programmable Power Division 179
8.4.2 MS704 General Commands
A number of MS704 commands are available to define the revision, mode of operation, nominal
frequency and EUT class to be used for the DO160 test. These general commands should be set
used to define the required test settings prior to calling any specific test step commands.
While most of the MS704 commands do not accept parameters or have a query format, the
general setup commands do as indicated in the table below.
Command Parameters
MS704:REVision A, B, C, D, E or F
MS704:GROup SAC, SVF, SXF, TAC, TVF
MS704:FREQuency <numeric value>
MS704:STEP SINGle or CONTinous
MS704:TEST:CONDition A letter form A to Z or AA to ZZ function of test.
MS704:FREQuency
This command will selects the nominal test frequency. For revisions D and E, the only available
setting is 400 Hz. For revision F (draft), available settings are 60 Hz, 360 Hz, 400 Hz, 600 Hz or
800 Hz. This command will only accept values that are consistent with the selected test group.
Refer to the table below for valid frequency settings by group.
GROUP Steady State Frequency in Hz
SAC 400
TAC 400
SVF 400 360 600 800
TVF 400 360 600 800
SXF 60
Table 8-1: MS704 Steady state frequency by group
The nominal frequency selection must be set prior to any test execution. Select the correct group
first so the frequency selected is indeed available.
Command Syntax MS704:FREQuency
Parameters 60 | 360 | 400 | 600 | 800
Examples MS704:FREQ 400
Query Syntax MS704:FREQ?
Returned Parameters <CRD>
MS704:GROUp
This command sets the EUT test group.
Command Syntax MS704:GROUp
Parameters SAC | TAC | SVF | TVF | SXF
Examples MS704:GROU SAC
Query Syntax MS704:GROU?
Returned Parameters <CRD>