Programming Manual Compact i / iX Series
AMETEK Programmable Power Division 74
LIST The waveform shape is controlled by the waveform shape list when a
triggered transient occurs.
Command Syntax [SOURce:]FUNCtion[:SHAPe]:MODE<mode>
Parameters FIXed | STEP | PULSe | LIST
*RST Value FIXed
Examples FUNC:MODE FIX
Query Syntax [SOURce:]FUNCtion[:SHAPe]:MODE?
Returned Parameters <CRD>
Related Commands FUNC FUNC:TRIG
FUNCtion:TRIGgered
This command selects the shape of the output voltage waveform when a triggered step or pulse
transient occurs. The parameters are:
SINusoid A sinewave is output
SQUare A squarewave is output
CSINusoid The output is a clipped sine waveform. Both positive and negative peak
amplitudes are clipped at a value determined by
SOURce:FUNCtion:SHAPe:CSINusoid.
<waveform_name> The output shape is described by one of the user-defined waveform
tables.
The maximum peak voltage that the AC source can output is 425 V peak. This includes any
combination of voltage and function shape values. Therefore, the maximum value that can be
programmed depends on the peak-to-rms ratio of the selected waveform. For a sinewave, the
maximum voltage that can be programmed is 300 V rms.
Command Syntax [SOURce:]FUNCtion[:SHAPe]:TRIGgered<shape>
Parameters SINusoid|SQUare|CSINusoid|<waveform_name>
*RST Value SINusoid
Examples FUNC:TRIG SIN FUNC:TRIG TABLE1
Query Syntax [SOURce:]FUNCtion[:SHAPe]:TRIGgered?
Returned Parameters <CRD>
Related Commands FUNC FUNC:MODEVOLT
FUNCtion:CSINusoid
This command sets the clipping level when a clipped sine output waveform is selected. The
clipping characteristics can be specified in two ways:
• The clipping level is expressed as a percentage of the peak amplitude at which clipping
occurs. The range is 0 to 100 percent. These are the default units when the optional THD
suffix is not sent.
• The clipping level is expressed at the percentage of total harmonic distortion in the output
voltage. The range is 0 to 43 percent. The optional THD suffix is sent to program in these
units.
Command Syntax [SOURce:]FUNCtion[:SHAPe]:CSINusoid<NRf>[THD]
Parameters 0 to 100% | 0 to 43% THD
*RST Value 100% | 0% THD (no clipping)
Examples FUNC:CSIN 80 FUNC:CSIN 10 THD
Query Syntax [SOURce:]FUNCtion[:SHAPe]:CSINusoid?
Returned Parameters <NR3>
Related Commands FUNC:MODE
Comentarios a estos manuales