Programming Manual Compact i / iX Series
AMETEK Programmable Power Division 186
Command Syntax MS704:ABNormal:VOLTage:TRANsient:OVER
Parameters none
Examples MS704:ABN:VOLT:TRAN:OVER
Query Syntax none
MS704:ABNormal:VOLTage:TRANsient:UNDer
This command will run the abnormal under voltage transients test.
Command Syntax MS704:NORMal:VOLTage:TRANsient:UNDer
Parameters none
Examples MS704:NORM:VOLT:TRAN:UND
Query Syntax none
MS704:ABNormal:VOLTage:TRANsient:COMBination
This command will run the abnormal combination voltage transients test.
Command Syntax MS704:ABNormal:VOLTage:TRANsient:COMBination
Parameters none
Examples MS704:ABN:VOLT:TRAN:COMB
Query Syntax none
MS704:ABNormal:FREQuency:TRANsient[:ALL]
This command will run all the abnormal frequency transients tests.
Command Syntax MS704:ABNormal:FREQuency:TRANsient[:ALL]
Parameters none
Examples MS704:ABN:FREQ:TRAN
Query Syntax none
MS704:ABNormal:FREQuency:TRANsient:OVER
This command will run the abnormal over frequency transients test.
Command Syntax MS704:ABNormal:FREQuency:TRANsient:OVER
Parameters none
Examples MS704:ABN:FREQ:TRAN:OVER
Query Syntax none
MS704:ABNormal:FREQuency:TRANsient:UNDer
This command will run the abnormal under frequency transients test.
Command Syntax MS704:ABNormal:FREQuency:TRANsient:UNDer
Parameters none
Examples MS704:ABN:FREQ:TRAN:UND
Query Syntax none
MS704:ABNormal:FREQuency:TRANsient:COMBination
This command will run the abnormal combination frequency transients test.