Programming Manual Compact i / iX Series
AMETEK Programmable Power Division 60
4.13 Output Subsystem
This subsystem controls the main outputs, the signal outputs, the power-on state, and the output
protection function of the i/iX Series.
Subsystem Syntax
OUTPut
[:STATe] <bool> Enable/disable output voltage, current, power, etc.
:DFI
[:STATE] <bool> Enable/disable DFI output
:SOURce <source> Selects an event source (QUES|OPER|ESB|RQS|OFF)
:PON
[:STATe] RST | RCL0 Set power-on state to *RST or *RCL0
:PROTection
:CLEar Reset latched protection
:DELay <n> Delay after programming/before protection
:RI
:MODE <mode> set remote inhibit input (LATC|LIVE|OFF)
:TTLTrg
:MODE TRIG | FSTR Sets or disabled Function strobe mode.
[:STATE] <bool> Enable/disable trigger out drive
:SOURce <source> Selects a TTLTrg source (BOT|EOT|LIST)
OUTPut
This command enables or disables the AC source output. The state of a disabled output is an
output voltage amplitude set to 0 volts, with output relays opened. When opening the output
relay, the output is set to 0 volt first, then the output relay is opened. A user settable delay may
be inserted before the output relay is opened. See the “PONSetup:RELay” command for details.
Your application program should allow for this delay. (default is 0.1 sec or 100 msec).
The query form returns the output state.
Command Syntax OUTPut[:STATe]<bool>
Parameters 0 | OFF | 1 | ON
*RST Value OFF
Examples OUTP 1 OUTP:STAT ON
Query Syntax OUTPut[:STATe]?
Returned Parameters 0 | 1
Related Commands *RCL *SAV PONS:REL
OUTPut:DFI
This command enables or disables the discrete fault indicator (DFI) signal to the power source.
Command Syntax OUTPut:DFI[:STATe]<bool>
Parameters 0|1|OFF|ON
*RST Value OFF
Examples OUTP:DFI 1 OUTP:DFI OFF
Query Syntax OUTPut:DFI[:STATe]?
Returned Parameters 0 | 1
Related Commands OUTP:DFI:SOUR
Comentarios a estos manuales