Vista de pagina 36
Programming Manual Compact i / iX Series
AMETEK Programmable Power Division 37
4.4 Diagnostic Subsystem
These subsystem commands perform diagnostic functions which include reading and writing to
the EEPROM, resetting the AC source and reading temperature.
Subsystem Syntax
DIAGnostic
:RESet Force power-on reset
:TEMPerature
:AMBient? Returns ambient temperature in °C
DIAGnostic:RESet
This commands forces a power-on reset.
Command Syntax DIAGnostic:RESet
Parameters None
Examples DIAG:RES
Related Commands *RST
DIAGnostic:TEMPerature:AMBient?
This query returns the temperature measured at the ambient sense thermistor in degrees C.
Query Syntax DIAGnostic:TEMPerature:AMBient?
Parameters None
Examples DIAG:TEMP:AMB?
Returned Parameters <NR3>